Nominal Diameter: DN25-DN400
Pressura nominal: 1.6Mpa/2.5Mpa/4.0Mpa
Ratio range: Max 40:1 (under P=101.325Kpa,T=293.15K)
Sagaciter: 1.5% (Latin), 1.0% (Libitum)
Repetitio: Melius 0.2%
Introductio
Applicationem
Technical data
Institutionem
Introductio
QTWG series gas turbinibus metri fluxus est nova generatio altae praecisiones et summus certae instrumenti mensurae gas praecisio, quae fundatur in technologia progressionis metrorum domesticorum et foris fluxus. Praeclaram humilitatis pressionem et altam pressionem metering observantiam, varios modos output insignes et sensum humilem ad perturbationem fluidi. Usus est late pro gas naturalibus, gas- carbonibus substructis, gas liquefactis aliisque applicationibus gasorum.
commoda
Gas Turbine flow Meter Commoda et Incommoda
Gas Turbine metri fluxus est cum technologia rectificationis provectae et structurae pulveri probationis. Cum sensoriis temperatura et pressione constructis, quae automatice recompensationem consequi possunt ut firmam accurationem habeant. Gas turbine metri fluxum praebet bonam solutionem custodiae inter partes translationis.
Cum praecessione vortex metri fluxus comparatus, metri gas turbinis fluxus est cum detrimento pressionis humilis, fluxus inchoationis humilis et latius mensurae mensurae. Ostentatio gas turbinis metri subsidium gyrationis 350° influunt, facile in varias partes lege data.
Applicationem
Gas Turbine profluente metra est maxime pro gas naturalibus, LPG, gas carbonibus etc. Late in variis industriarum gasis metering et gas pressionis moderandis stationibus adhibentur sicut petroleum, chemicum, electricum, energiae industriae, gas transmissio et distributio reticulorum pipelini et gasi urbana naturalis gas metering.
Naturalis Gas
Naturalis Gas
Petroleum
Petroleum
Chemical
Chemical
Electric Power.
Electric Power.
Industriae Boilers
Industriae Boilers
Gas Metering
Gas Metering
Technical data

Tabula 1:  Gas Turbine Fluxus Meter Parameters

Nominal Diameter DN25-DN400
Nominal Pressura 1.0Mpa/1.6Mpa/2.5Mpa/4.0Mpa
Ratio range Max 40:1 (under P=101.325Kpa,T=293.15K)
Sagaciter 1.5% (Latin), 1.0 (Libitum)
Repeatability Melius 0.2%
Probatur explosio ExiallCT6Ga
Praesidium IP65
Testa Material Aluminium Alloy/Carbon Steel
Potestas Supple 3.6V Lithum Pugna Powered
Potestas externa DC18-30V
output signum 4-20mA, Pulsus, Alarm
Communicationis RS485 Modbus RTU

Table 2: Gas Turbine Flow Meter Dimension

Magnitudo L D K N-φh H W Dicta
DN25(1") 200 115 85 4-φ14 335 200 1.Flange informationes secundum PN16 GB9113.1-2000

2.Other flanges sunt available
DN40(1½") 200 150 110 4-φ18 365 230
DN50(2") 150 165 125 4-φ18 375 275
DN80(3") 240 200 160 8-φ18 409 280
DN100(4") 300 220 180 8-φ18 430 285
DN150(6") 450 285 240 8-φ22 495 370
DN200(8") 600 340 295 12-φ22 559 390
DN250(10") 750 405 355 12-φ26 629 480
DN300(12") 900 460 410 12-φ26 680 535
DN400(16") 1200 580 525 16-φ30 793 665

Table III: Gas Turbine Flow Meter Flow Range

DN
(mm/inch)
Model Fluunt speciem Flow range (m3/h) Qmin (m3/h) Max.pressur e loss (Kpa) Testa materia Pondus (kg)
DN25(1″) QTWG-25(A) G50 5-50 ≤1 1 ≤1.6MPa
Aluminium Alloy
≥2.0MPa
Carbon ferro vel SS304
7
DN40(1½″) QTWG-40(A) G60 6-60 ≤1 1 8
50(2") QTWG-50(A) G40 6.5-65 ≤1.3 0.9 8.5
QTWG-50(B) G65 8-100 ≤1.6 0.8
QTWG-50(C) G100 10-160 ≤2.4 2.0
80(3") QTWG-80(A) G100 8-160 ≤2.4 1.0 9.5
QTWG-80(B) G160 13-250 ≤3.0 1.6
QTWG-80(C) G250 20-400 ≤5.0 2.0
100 (4") QTWG-C(A) G160 13-250 ≤3.3 1.0 15
QTWG-C(B) G250 20-400 ≤4.2 1.6
QTWG-C(C) G400 32-650 ≤6.7 1.8
150(6") QTWG-150(A) G400 32-650 ≤7.8 1.6 27
QTWG-150(B) G650 50-1000 ≤10 2.0
QTWG-150(C) G1000 80-1600 ≤12 2.3
200(8") QTWG-200(A) G650 50-1000 ≤13 1.6 Carbon Ferro aut SS304 45
QTWG-200(B) G1000 80-1600 ≤16 2.0
QTWG-200(C) G1600 130-2500 ≤20 2.2
250(10") QTWG-250(A) G1000 80-1600 ≤20 1.2 128
QTWG-250(B) G1600 130-2500 ≤22 2.0
QTWG-250(C) G2500 200-4000 ≤25 2.3
300 (12") QTWG-300(A) G1600 130-2500 ≤22 1.6 265
QTWG-300(B) G2500 200-4000 ≤25 2.0
QTWG-300(C) G4000 320-6500 ≤35 2.3
400(16") QTWG-400(A) G1600 300-2500 ≤25 1.8 380
QTWG-400(B) G2500 500-4000 ≤35 2.0
QTWG-400(C) G4000 600-8000 ≤40 2.3

Table 4: Gas Turbine flow Meter Model Electio

QTWG Morbi laoreet XXX X X X X X X X
Magnitudo (mm) DN25-DN400mm
Sagaciter 1.5% (vexillum) 1
1.0% 2
Nominal 1.0MPa 1
Pressura 1.6MPa 2
2.5MPa 3
4.0MPa 4
alii 5
Corpus Material Aluminium Ally (Pro magnitudine infra DN150mm) 1
Chalybe 2
Diver 3
Output/communication Pulsus+4-20mA 1
Pulsus+4~20mA+485 3
Pulsus+4~20mA+HART 4
Potestas Supple Pugna Powered + potentia externa DC24V (duo-filum) 1
Pugna Powered + potentia externa DC24V (tribus filum) 2
Ex-probatio cum 1
Sine 2
Institutionem
Installation opus est Gas Turbine flow Meter
Ut mensurae stabilem et accuratam fluxum obtineant, magni momenti est ut metrum fluens recte in organo organo instituatur
Fluxus meter necesse est ut in pipeline horizontali instituatur. Interior diametri fluxus metrorum necesse est esse eandem cum diametro pipelini interiorem, et axis fluens metri concentricus cum axi pipelini in institutione.
Suadeo ut domesticas install. Si opus est ut foris instituat, quaeso fac praesidium bonum a directo solis et pluviae
Ad usum ordinarium medii curandum non afficitur cum metri fluxus subtrahitur, valvae clausulae in flumine et amni metri fluxu institui debent. A bypass pipeline parari. Valvae fluens imperium in amni profluentis metri constitui debet, et valvae fluminis cum metri fluxu metro plene aperiri debent.

Gas Turbine flow Meter Sustentacionem
Gas Turbine fluere meter necesse est ut oleum implens operationem regulariter ut gestus ad aequaliter operandum curet.
Operatio oleum implens indicium est in singulis corporis metris Q&T gas turbine fluxum. Sequere indicationem facere oleum saturitatem regulariter pulchrum est.
Mitte Inquisitionis
Eportatus in plusquam 150 terris in circuitu, capacitas productionis M/mensis!
Copyright © Q&T Instrument Co., Ltd. All Rights Reserved.
Support: Coverweb