Products
Electromagnetica aqua metri
Electromagnetica aqua metri
Electromagnetica aqua metri
Electromagnetica aqua metri

Electromagnetica aqua metri

Magnitudo: DN50--DN800
Pressura nominal: 0.6-1.6Mpa
Sagaciter: ±0.5%R, ±0.2%R (Libitum)
Electrode materia: SS316L, HC, Ti, Tan
Ambientium, temperatus: -10℃--60℃
Introductio
Applicationem
Technical data
Institutionem
Introductio
Elaqua ectromagnetica metri genus est instrumenti ad mensurandum volumen fluxum liquoris conductivi innixum in principio inductionis electromagneticae Faraday. Notas habet late range, humilis fluxus initialis, humilis pressionis damnum, mensurae realis tempus, mensurae cumulativae, mensurae bi-directionis, etc. Maxime utitur DMA zoning, magna vigilantia, aquae iactura analysi et statistica compositio aquae copiae. .
commoda
1 Nullae partes interclusio intra tubum metiendi, depressum pressionis damnum et humilem requisita pro pipeline recta.
2 Variabilis diameter designans, emendare mensurae subtilitatem et sensibilitatem, reducere consummationem virtutis excitationem.
3. Electrodes et lineos idoneos selige, cum bene corrosione resistentia et resistentia indue.
4. Plenum consilium electronicum, valida anti-impedimenti facultas, mensura certa, alta accuratio, amplitudo amplitudinis.
Applicationem
Electromagneticum aquaticum metrum est instrumentum metri metrorum specialiter destinatum ad ipsas exigentias aquarum inceptis, ad industriam aquae specialiter destinatum, quae aquam optimize potest et accurate mensurare et compositionem artis aquae curare. Usu probatum est aquae metri electromagneticae specimen electionis esse solvendae mensurae contradictionis magnarum aquarum utentium. Praeterea metra aquae electromagneticae late adhibentur in industria chemica, tutela environmental, metallurgia, medicina, charta confectio, copia aquae et INCILE et aliae technologiae industriae et administrationis Dicasteriorum.
Urbs aquae copia
Urbs aquae copia
Fundus irrigationis
Fundus irrigationis
Vastum aqua curatio
Vastum aqua curatio
Oleum industriam
Oleum industriam
Pharmaceuticals industria
Pharmaceuticals industria
Aquarum et INCILE
Aquarum et INCILE
Technical data

Tabula 1: Electromagnetica aqua metri Technical Data

Executive vexillum GB/T778-2018          JJG162-2009
Influunt directionem Positivum/negative/net flow
Ratio range R160/250/400(Libitum.
Sagaciter Classis 1 classis/2 classLibitum
Nominal Diameter(mm) DN50 DN65 DN80 DN100 DN125 DN150 DN200 DN250 DN300
Nominal Flow Rate(m3/h) 40 63 100 160 250 400 630 1000 1600
Pressura damnum P40
Temperature T50
Pressura 1.6MPa(Special pressura potest nativus
Conductivity ≥20μS/cm
Coepi fluxus velocitatis 5mm/s
Output 4-20mA, Pulsus
Fluunt profile sensus genus U5,D3
Electromagnetica convenientiae E2
Connection Type Flanged,GB/T9119-2010
Praesidium IP68
Ambientium, temperatus -10℃~+75℃
Relativum humiditas 5%~95%
Genus institutionem Horizontalis et verticalis
Electrode materia 316L
Corpus materiale Carbon chalybs/ ferrum immaculatum (libitum)
Grounding modum Cum aut sine grounding/fundens circulum / grounding electrode (libitum)
Productum Electio
Base

Wireless IOT

Transmissio remotus wireless fluxus et pressionis

Transmissio remota fluxus et pressura
Output / GPRS/Nbiot GPRS/Nbiot/Presura remote RS485/TTL
Communicationis / CJT188, MODBUS CJT188, MODBUS CJT188, MODBUS
Potestas Supple DC3.6V Lithium altilium DC3.6V Lithium altilium DC3.6V Lithium altilium DC3.6V Lithium altilium
Structura Type Integra et remota type Integra et remota type Integra et remota type Integra et remota type
Unitates Exaggeratus fluxus: m3
Fluxus instantaneus: m3/h
Exaggeratus fluxus: m3
Fluxus instantaneus: m3/h
Exaggeratus fluxus: m3
Fluxus momentaneus: m3/h                         MPa
Exaggeratus fluxus: m3
Fluxus instantaneus: m3/h
Applicationem Potest reponere aqua metri, ultra-low pressionis detrimentum, nullum indumentum Real-time and effective remote meter reading Scitote fistulam retis pressionem vigilantiam et intelligentem terminum metering et vigilantiam praebere ad informationem de inceptis constructionis inceptis aquarum (SCADA, GIS, exemplar, exemplar hydrauticum, celeritas scientifica) Wired remotis

Table 2:metire dolor

Diameter
(mm)
Ratio range
(R)Q3/Q1
Fluunt Rate(m3/h)
Min flow
Q1
Terminus
Q2
Nomal flow
Q3
ONERO
influunt Q4
50 400 0.1 0.16 40 50
65 400 0.16 0.252 63 77.75
80 400 0.25 0.4 100 125
100 400 0.4 0.64 160 200
125 400 0.625 1.0 250 312.5
150 400 1.0 1.6 400 500
200 400 1.575 2.52 630 787.5
250 400 2.5 4.0 1000 1250
300 400 4.0 6.4 1600 2000
Institutionem
Installation environment delectu
1. Vade machinas cum validis campis electromagneticis. Tam magnus motor, magnus commutator, magna frequentia armorum conversionis.
2. Institutio situs validam vibrationem non habere debet, et temperatus ambiens multum non mutat.
3. Commodum ad institutionem et sustentationem.


Electio institutionis locus

1. Directio fluens notam in sensori congruere debet cum directione medii mensurati in pipelineo.
2. Institutionem positio curare debet ut tubus mensurae semper medio mensurato impleatur.
3. Locum in quo pulsus fluidus fluit, est parvus, id est, procul ab aqua sentina et partium resistentiae localis (valvae, cubiti, etc.).
4. Cum mensuret duos tempus fluidum, locum elige non facile ad tempus separationis causandum.
5. Fuge institutionem in area cum pressura negativa in fistula.
6. Cum medium mensuratum facile efficiat electrodam et murum interiorem tubi mensurae ad adhaerendum et scalam, commendatur ut rate fluxus in tubo mensurae non minus quam 2m/s sit. Hoc tempore, tubus leviter attenuatus quam processus tubus adhiberi potest. Ut electrode purgare et tubum mensurare sine intermissione in tubo processuali influat, sensor in parallela cum portu purgatorio institui potest.


Fluminis recta fistula sectionem requisitis

Requisita sensoris in flumine recto fistulae sectionem in schemate monstrantur. Cum diametri fluminis et amni rectae fistulae sectiones cum electromagneticae aquae frigidae metri metro dissentiunt, fistula attenuata vel fistula attenuata inaugurari debet, et angulus conicus minor quam 15° (7°-8° est. malebat) ac deinde cum tibia iungitur.
Resistentia fluminis
components

Nota: L est tuam rectam longitudinem 
Recta fistulam requisita L=0D pro a . considerari potest
fistulam directam sectionem
L≥5D L≥10D
Nota :(L est longitudo sectio fistulae rectae, D diametrum sensorem nominalem)
Mitte Inquisitionis
Eportatus in plusquam 150 terris in circuitu, capacitas productionis M/mensis!
Copyright © Q&T Instrument Co., Ltd. All Rights Reserved.
Support: Coverweb