Produk
Vortex Flowmeter Kab
Vortex Flowmeter Kab
Vortex Flowmeter Kab
Vortex Flowmeter Kab

Temperatur & Kompensasi Tekanan Vortex Flow Meter

Ukuran medium: Cairan, Gas, Uap
Suhu Sedheng: -40℃~+200℃; -40℃~+280℃; 40℃~+350℃
Tekanan Nominal: 1.6MPa; 2.5MPa; 4.0MPa; 6.4MPa (Tekanan liyane bisa custom, kudu takon supplier)
Akurasi: 1,0% (Flange), 1,5% (Sisipan)
Bahan: SS304 (Standar), SS316 (Opsional)
Pambuka
Aplikasi
Data Teknis
Instalasi
Pambuka
Meter aliran vortex flange digunakake ing pirang-pirang cabang industri kanggo ngukur aliran volume cairan, gas lan uap. Aplikasi ing industri kimia lan petrokimia, contone, ing pembangkit listrik lan sistem pasokan panas nglibatake cairan sing beda-beda: uap jenuh, uap superheated, udara tekan, nitrogen, gas cair, gas buang, karbon dioksida, banyu demineralisasi kanthi lengkap, pelarut, lenga transfer panas, banyu feed boiler, kondensat, lsp.


Kaluwihan
Vortex flow meter kaluwihan lan cacat
Awak meter aliran Vortex kuwat lan ditrapake sacara universal kanggo cairan, gas lan uap, dioptimalake kanggo aplikasi uap.
Kanggo pangukuran gas, yen suhu lan tekanan gas diganti akeh, kompensasi tekanan lan suhu kudu dibutuhake, meter aliran vortex bisa nambah kompensasi suhu lan tekanan.
Q & T Vortex flow meter nganggo teknologi lan desain OVAL Jepang.
Kanggo nglindhungi sensor, Q&T vortex flow meter milih sensor sing dipasang, kanthi 4 kristal piezo-listrik sing dibungkus ing sensor, yaiku paten kita dhewe.
Ora ana bagean sing obah, ora ana abrasi, bagian sing ora ana ing njero sensor meter aliran vortex, awak SS304 sing dilas kanthi lengkap (SS316 bisa dipilih).
Kanthi sensor paten lan awak sensor aliran, meter aliran Q&T vortex bisa ngilangi pengaruh drift & geter saka aspek sing apik ing situs kerja nalika dibandhingake karo meter aliran liyane.
Kajaba saka meter aliran elektromagnetik lan meter aliran ultrasonik bisa digunakake minangka meter aliran lan meter BTU, nambah sensor suhu lan totalizer, meter aliran vortex uga bisa digunakake minangka meter BTU lan ngukur energi uap utawa banyu panas.
Mbutuhake konsumsi daya sithik banget: 24 VDC, maksimal 15 Watt;
Ing pangukuran gas, vortex flow meter bisa entuk akurasi dhuwur ± 0,75% ~ ± 1,0% maca (gas ± 1,0%, Cairan ± 0,75%); sing bisa digunakake ing transfer ditahan, nalika rotameter tabung logam utawa piring orifice biasane digunakake kanggo kontrol proses.
Kanthi macem-macem output sinyal lan pilihan, kayata 4-20mA, pulsa karo HART utawa pulsa karo RS485 bisa dipilih.
Ing piranti elektronik kanggo ngukur aliran, vortex flow meter minangka siji-sijine sing bisa nolak sawetara suhu sing amba nganti suhu paling dhuwur 350 ℃, meter aliran digital suhu proses paling dhuwur.
Aplikasi
Aplikasi vortex flow meter
Vortex flow meter profesional kanggo ngukur cairan non-konduktif, gas, uap jenuh lan superheated, utamane kanggo pemukiman perdagangan pangukuran uap.
Kajaba digunakake minangka meter aliran, meter aliran vortex uga bisa digunakake minangka meter panas kanggo ngukur panas reged uap lan banyu panas.
Pengukur aliran Vortex biasane ngawasi output kompresor lan evaluasi Free Air Delivery (FAD)
Ana akeh gas industri, kayata gas alam, gas nitrogen, gas cair, gas flue, karbon dioksida, lsp, kabeh bisa nggunakake vortex flow meter.
Ing pirang-pirang pabrik, pemantauan udara sing dikompres penting banget, meter aliran vortex uga bisa digunakake kanggo kontrol proses.
Saliyane pangukuran gas sing beda, meter aliran vortex uga bisa digunakake kanggo lenga entheng utawa banyu sing diresiki, kayata lenga termal, banyu desalinasi, banyu demineral, banyu RO, banyu feed ketel, banyu kondensat, lsp.
Ing industri Kimia lan petrokimia, ana uga akeh gas utawa cairan sing bisa nggunakake meter aliran vortex kanggo ngawasi.
Perawatan banyu
Perawatan banyu
Industri Pangan
Industri Pangan
Industri Farmasi
Industri Farmasi
Petrokimia
Petrokimia
Industri Kertas
Industri Kertas
Pengawasan kimia
Pengawasan kimia
Industri Metalurgi
Industri Metalurgi
Drainase Umum
Drainase Umum
Industri Batubara
Industri Batubara
Data Teknis

Tabel 1: Data Teknis Vortex Flow Meter

Diukur Sedheng Cairan, Gas, Uap
Suhu Sedheng -40℃~+200℃; -40℃~+280℃; 40℃~+350℃
Tekanan Nominal 1.6MPa; 2.5MPa; 4.0MPa (tekanan liyane bisa custom, kudu takon supplier)
Akurasi 1,0% (Flange), 1,5% (Sisipan)
Rasio jarak pangukuran 1:10 (Kondisi udara standar minangka referensi)
1:15 (Cairan)
Range Aliran Cairan: 0.4-7.0m/s; Gas: 4.0-60.0m/s; Uap: 5.0-70.0m/s
Spesifikasi DN15-DN300 (Flange), DN80-DN2000 (Sisipan), DN15-DN100 (Benang), DN15-DN300 (Wafer), DN15-DN100 (Sanitary)
Bahan SS304 (Standar), SS316 (Opsional)
Koefisien Mundhut Tekanan Cd≤2.6
Akselerasi geter Diijini ≤0,2g
IEP ATEX II 1G Ex ia IIC T5 Ga
Kondisi Lingkungan Suhu sekitar: -40 ℃ -65 ℃ (situs non-bledosan); -20 ℃ -55 ℃ (situs bledosan-bukti)
Kelembapan relatif: ≤85%
Tekanan: 86kPa-106kPa
Power Supply 12-24V/DC utawa 3.6V baterei powered
Sinyal Output Sinyal frekuensi pulsa 2-3000Hz, Low level≤1V, high level≥6V
Sistem loro-kawat 4-20 sinyal (output terisolasi), Load≤500

Tabel 2: Gambar Struktur Pengukur Aliran Vortex

Temperatur & Pressure Compensation Vortex Flow Meter ( Sambungan Flange: DIN2502  PN16) Gambar Struktur
Kaliber (mm) Diameter njero D1 (mm) Dawane  L (mm) Diameter njaba flange D3 (mm) Diameter tengah Lubang Bolts B(mm) Ketebalan Flange C (mm) Diameter Lubang Bolt D (mm) Jumlah Screw N
25 25 170 115 85 16 14 4
32 32 170 140 100 16 18 4
40 40 190 150 110 16 18 4
50 50 190 165 125 18 18 4
65 65 220 185 145 18 18 4
80 80 220 200 160 20 18 8
100 100 240 220 180 20 18 8
125 125 260 250 210 22 18 8
150 150 280 285 240 22 22 8
200 200 300 340 295 24 22 12
250 250 360 405 355 26 26 12
300 300 400 460 410 28 26 12

Tabel 3: Vortex Flow Meter Flow Range

Ukuran (mm) Cairan (Medium referensi: banyu suhu normal, m³ / h) Gas (Medium referensi: 20 ℃, 101325pa kondisi udara, m³ / h)
Standar ditambahi Standar ditambahi
15 0.8~6 0.5~8 6~40 5~50
20 1~8 0.5~12 8~50 6~60
25 1.5~12 0.8~16 10~80 8~120
40 2.5~30 2~40 25~200 20~300
50 3~50 2.5~60 30~300 25~500
65 5~80 4~100 50~500 40~800
80 8~120 6~160 80~800 60~1200
100 12~200 8~250 120~1200 100~2000
125 20~300 12~400 160~1600 150~3000
150 30~400 18~600 250~2500 200~4000
200 50~800 30~1200 400~4000 350~8000
250 80~1200 40~1600 600~6000 500~12000
300 100~1600 60~2500 1000~10000 600~16000
400 200~3000 120~5000 1600~16000 1000~25000
500 300~5000 200~8000 2500~25000 1600~40000
600 500~8000 300~10000 4000~40000 2500~60000

Tabel 4: Nilai Kapadhetan Uap Superpanas (tekanan & suhu relatif)              Unit: Kg/m3

Tekanan Absolut (Mpa) Suhu (℃)
150 200 250 300 350 400
0.1 0.52 0.46 0.42 0.38
0.15 0.78 0.70 0.62 0.57 0.52 0.49
0.2 1.04 0.93 0.83 0.76 0.69 0.65
0.25 1.31 1.16 1.04 0.95 0.87 0.81
0.33 1.58 1.39 1.25 1.14 1.05 0.97
0.35 1.85 1.63 1.46 1.33 1.22 1.13
0.4 2.12 1.87 1.68 1.52 1.40 1.29
0.5 2.35 2.11 1.91 1.75 1.62
0.6 2.84 2.54 2.30 2.11 1.95
0.7 3.33 2.97 2.69 2.46 2.27
0.8 3.83 3.41 3.08 2.82 2.60
1.0 4.86 4.30 3.88 3.54 3.26
1.2 5.91 5.20 4.67 4.26 3.92
1.5 7.55 6.58 5.89 5.36 4.93
2.0 8.968 7.97 7.21 6.62
2.5 11.5 10.1 9.11 8.33
3.0 14.2 12.3 11.1 10.1
3.5 17.0 14.6 13.0 11.8
4.0 17.0 15.1 13.6

Tabel 5: Pamilihan Model Vortex Flow Meter

LUGB XXX X X X X X X X X X
Kaliber
(mm)
Kode Referensi DN15-DN300,
mangga priksa tabel kode kaliber 10
Nominal
Tekanan
1.6Mpa 1
2,5 Mpa 2
4.0Mpa 3
liyane 4
Sambungan Flange 1
wafer 2
Tri-clamp (Sanitary) 3
Utas 4
sisipan 5
liyane 6
Sedheng Cairan 1
Gas Umum 2
Uap jenuh 3
Superheated Steam 4
liyane 5
Tandha Khusus Normal N
Output Sinyal Standar M
Intrinskal aman Explosion-bukti B
Ing Tampilan Situs X
Suhu Dhuwur (350 ℃) G
Kompensasi Suhu W
Kompensasi Tekanan Y
Kompensasi Suhu & Tekanan Z
Struktur
Jinis
Kompak/Integral 1
remot 2
Power Supply DC24V D
Baterei Lithium 3.6V E
liyane G
Output
Sinyal
4-20mA A
Pulsa B
4-20mA, HART C
4-20mA/Pulse,RS485 D
4-20mA/Pulse,HART E
liyane F
Flange Standar DIN PN16 1
DIN PN25 2
DIN PN40 3
ANSI 150# A
ANSI 300# B
ANSI 600# C
JIS 10K D
JIS 20K E
JIS 40K F
liyane G
Instalasi
1. Instalasi vortex flow meter nduweni syarat sing luwih dhuwur, kanggo njamin akurasi sing luwih apik lan bisa digunakake kanthi bener. Instalasi meter aliran Vortex kudu adoh saka motor listrik, konverter frekuensi gedhe, kabel listrik, trafo, lsp.
Aja nginstal ing posisi sing ana bend, klep, fitting, pompa, lsp, sing bisa nyebabake gangguan aliran lan mengaruhi pangukuran.
Garis pipa lurus ngarep lan sawise garis pipa lurus kudu ngetutake saran ing ngisor iki.
Concentric Reducer Pipeline


Concentric Expansion Pipeline

Tunggal Square Bend
Loro Square Bends ing bidang sing padha
Loro Square Bends Ing Pesawat Beda

Regulating Valve, Setengah mbukak Gate Valve
2. Vortex mili meter pangopènan saben dina
Reresik reguler: Probe minangka struktur penting saka flowmeter vortex. Yen bolongan deteksi probe diblokir, utawa entangled utawa kebungkus dening obyek liyane, iku bakal mengaruhi pangukuran normal, asil ing asil ora akurat;
Perawatan tahan lembab: sebagian besar probe durung ngalami perawatan tahan lembab. Yen lingkungan panggunaan relatif lembab utawa ora garing sawise diresiki, kinerja meter aliran vortex bakal kena pengaruh nganti sawetara, nyebabake operasi sing ora apik;
Nyilikake interferensi eksternal: periksa kanthi ketat kondisi grounding lan shielding meter aliran kanggo mesthekake akurasi pangukuran meter aliran;
Aja geter: Ana sawetara bagean ing flowmeter vortex. Yen ana geter sing kuat, bakal nyebabake deformasi utawa fraktur internal. Ing wektu sing padha, supaya ora mlebu cairan korosif.