Produk
Vertikal Tampilan Variabel Area Flowmeter
Vertikal Tampilan Variabel Area Flowmeter
Vertikal Tampilan Variabel Area Flowmeter
Vertikal Tampilan Variabel Area Flowmeter

Vertikal Tampilan Variabel Area Flowmeter

Rasio kisaran: 10:1 (Tipe Khusus 20:1)
Kelas Akurasi: 2.5 (Tipe khusus 1.5% utawa 1.0%)
Tekanan kerja: DN15~DN50 PN16 (Tipe khusus 2.5MPa)
Suhu sedheng: Tipe normal -80 ℃ ~ + 220 ℃
Suhu lingkungan: -40 ℃ ~ + 120 ℃ (Remote tampilan tanpa LCD≤85 ℃).
Pambuka
Aplikasi
Data Teknis
Instalasi
Pambuka
LZ seri cerdas Vertikal Tampilan Variabel Area Flowmeter adopts majeng internasional Honeywell tanpa kontak lan ora hysteresis ndeteksi owah-owahan ing Sudut Magnetik kolom sensor Magnetik, lan karo kinerja dhuwur MCU, kang bisa éling tampilan LCD: aliran cepet, aliran total, daur ulang. current.environment temperature, damping time, small signalremoval.Optional 4 ~ 20mA tranmission (karo komunikasi HART), output pulsa, fungsi output weker watesan dhuwur lan kurang, etc, jinis pemancar sinyal cerdas nduweni presisi dhuwur lan linuwih, sing bisa kanthi lengkap ngganti instrumen sing diimpor kanthi jinis sing padha, lan uga nduweni kinerja rega sing dhuwur, standarisasi parameter online lan proteksi kegagalan daya, lsp.
Kaluwihan
Keuntungan Flowmeter Area Variabel Tampilan Vertikal:
1. Kanthi gandheng awak stainless steel,Awet nggunakake.
2. Independen saka kahanan fisik lan kimia medium kayata konduktivitas, konstanta dielektrik, lsp.
3. Ditrapake kanggo kabeh jinis lingkungan medium kayata korosif, beracun lan mbledhos.
4. Pangukuran antarmuka utawa pangukuran level 2 jinis medium kanthi kapadhetan sing beda.
5. Gampang diwaca tampilan ing kabeh jinis aliran meter.
6.Two-kabel 4 ~ 20mADC output sinyal kasedhiya.
Aplikasi
Vertikal Tampilan Variabel Area Flowmeter Aplikasi
Tampilan Vertikal Variabel Area Flowmeter utamane cocok kanggo pangukuran aliran cilik lan medium saka siji-phase Cairan utawa gas karo diameteripun pipe cilik lan medium, gangguan kurang lan nomer Reynolds asam asetat, kayata Air, Banyu, lenga pelumas, Uap, Hidrogen, O2 ,etc,lan akeh Cairan utawa gas liyane ing Kimia, Farmasi, Petrokimia, Pangan, Industri Metalurgi, lsp.
Perawatan banyu
Perawatan banyu
Industri Pangan
Industri Pangan
Industri Farmasi
Industri Farmasi
Petrokimia
Petrokimia
Industri Kertas
Industri Kertas
Pengawasan kimia
Pengawasan kimia
Industri Metalurgi
Industri Metalurgi
Drainase Umum
Drainase Umum
Industri Batubara
Industri Batubara
Data Teknis

Tabel 1: Lembar Data Flowmeter Area Variabel Tampilan Vertikal

Rentang pangukuran

Banyu (20 ℃)                  16~150000 l/h.

Udhara (0,1013MPa 20 ℃)       0,5 ~ 4000 m3/h.

Rasio kisaran 10:1 (Tipe Khusus 20:1).
Kelas akurasi 2.5 (Tipe khusus 1.5% utawa 1.0%).
Tekanan kerja

DN15~DN50 PN16 (jinis khusus 2.5MPa).

DN80~DN150 PN10 (Tipe khusus 1.6MPa).

Rating tekanan jaket 1.6MPa.

Suhu sedheng

Tipe normal -80 ℃ ~ + 220 ℃.

Tipe suhu dhuwur 300 ℃. Diantrekake karo jinis FEP ≤85 ℃.

Suhu sekitar

-40 ℃ ~ + 120 ℃ (Remote tampilan tanpa LCD≤85 ℃).

(Remote tampilan karo LCD≤70 ℃).

Viskositas dielektrik

1/4” NPT, 3/8” NPT 1/2” NPT≤5mPa.s

3/4" NPT, 1" NPT ≤250mPa.s

Output

Sinyal standar: sistem rong kabel 4 ~ 20mA (karo komunikasi HART).

Sinyal standar: sistem telung kabel 0 ~ 10mA.

Sinyal weker: 1. Output relay rong arah.

2.Saklar siji-cara utawa loro-pendekatan.

Output sinyal pulsa: 0-1KHz output terisolasi.

Proses sambungan

Tipe standar: 24VDC±20%.

Tipe AC: 220VAC(85~265VAC) (opsional).

Mode sambungan

Flange

Utas

Tri-jepit

Tingkat pangayoman

IP65/IP67.

Ex-mark

Intrinsik aman: ExiaIICT3~6. Jinis Exd: ExdIICT4~6.

Tabel 2: Tampilan Vertikal Variabel Area Flowmeter Rentang Aliran

Kaliber

(mm)

Nomer kerja Range aliran Penurunan tekanan kpa

Banyu L/h

Udhara m3/h Banyu Kpa hawa
Tipe normal Tipe anti karat Tipe normal
Tipe anti karat

Tipe normal

Tipe anti karat
15 1A 2.5~25 -- 0.07~0.7 6.5 - 7.1
1B 4.0~40 2.5~25 0.11~1.1 6.5 5.5 7.2
1C 6.3~63 4.0~40 0.18~1.8 6.6 5.5 7.3
1D 10~100 6.3~63 0.28~2.8 6.6 5.6 7.5
1E 16~160 10~100 0.48~4.8 6.8 5.6 8.0
1F 25~250 16~160 0.7~7.0 7.0 5.8 10.8
1G 40~400 25~250 1.0~10 8.6 6.1 10.0
1H 63~630 40~400 1.6~16 11.1 7.3 14.0
25 2A 100~1000 63~630 3~30 7.0 5.9 7.7
2B 160~1600 100~1000 4.5~45 8.0 6.0 8.8
2C 250~2500 160~1600 7~70 10.8 6.8 12.0
2D 400~4000 250~2500 11~110 15.8 9.2 19.0
40 4A 500~5000 300~3000 12~120 10.8 8.6 9.8
4B 600~6000 350~3500 16~160 12.6 10.4 16.5
50 5A 630~6300 400~4000 18~180 8.1 6.8 8.6
5B 1000~10000 630~6300 25~250 11.0 9.4 10.4
5C 1600~16000 1000~10000 40~400 17.0 14.5 15.5
80 8A 2500~25000 1600~16000 60~600 8.1 6.9 12.9
8B 4000~40000 2500~25000 80~800 9.5 8.0 18.5
100 10A 6300~63000 4000~40000 100~1000 15.0 8.5 19.2
150 15A 20000~100000 -- 600~3000 19.2 -- 20.3

Tabel 3: Pamilihan Model Flowmeter Area Variabel Tampilan Vertikal

QTLZ X X X X X X X X X
Indikator Kode
Indikator lokal Z
Indikator LCD karo ouput D
diameteripun normal Kode
DN15 -15
DN20 -20
DN25 -25
DN40 -40
DN50 -50
DN80 -80
DN100 -100
DN150 -150
Struktur Kode
Ngisor-ndhuwur /
Kiri-tengen (horizontal) H1
Kanan-kiwa (horizontal) H2
Sisih-sisih AA
Sisih ngisor LA
Sambungan benang S
Tri-jepit M
Bahan awak Kode
304SS R4
316LSS R6L
Hastelloy C Hc4
titanium Ti
Liner F46(PTFE) F
Monel M
Jinis indikator Kode
Iinear indicator (indikator pointer) M7
Indikator nonlinier (LCD Display) M9
Fungsi kombinasi (mung kanggo tampilan LCD) Kode
24VDC karo output 4 ~ 20mA S
24VDC karo komunikasi HART Z
daya baterei D
Fungsi tambahan Kode
Tabung ukur kanthi pengawetan termal / jaket insulasi panas T
Ukur suhu medium sing luwih dhuwur tinimbang 120.C HT
Ex-bukti: Kode
karo W
tanpa N
weker Kode
Weker siji K1
Weker loro K2
ora ana N
Instalasi
Pemasangan Rotameter Tabung Logam
Flowmeter sing dipasang kudu njamin entri ≥5DN bagean pipa lurus, ngekspor bagean pipa lurus ora kurang saka 250mm ; yen medium ngemot bahan ferromagnetik , Filter magnet kudu dipasang ing ngarep flowmeter 。(deleng filter magnetik  lan diagram diagram bagean pipa lurus )

1. Kanggo meter aliran dipasang, priksa manawa pipa ukuran tegak luwih apik tinimbang 5 lan kudu dilengkapi bypass, gampang dijaga lan resik lan ora mengaruhi produksi.
2. Sistem ngawasi lan kontrol ing katup kontrol,kudu dipasang hilir flowmeter.Kanggo pangukuran gas,Kudu mesthekake tekanan kerja ora kurang saka 5 kaping mundhut meksa saka flowmeter, kanggo nggawe karya stabil flowmeter.
3. Sadurunge nginstal flowmeter, pipa kudu welding slag purging resik; Nalika instalasi kanggo mbusak komponen ngunci ing meter aliran; nalika digunakake sawise instalasi, Alon-alon mbukak tutup kontrol, Aja karusakan kejut  flow meter
Kirim Pitakonan Panjenengan
Diekspor menyang luwih saka 150 negara ing ndonya, 10000 set / kapasitas produksi sasi!
Hak cipta © Q&T Instrument Co., Ltd. Kabeh hak dilindhungi undhang-undhang.
Nyokong: Coverweb