Rasio kisaran: 10:1 (Tipe Khusus 20:1)
Kelas Akurasi: 2.5 (Tipe khusus 1.5% utawa 1.0%)
Tekanan kerja: DN15~DN50 PN16 (Tipe khusus 2.5MPa)
Suhu sedheng: Tipe normal -80 ℃ ~ + 220 ℃
Suhu lingkungan: -40 ℃ ~ + 120 ℃ (Remote tampilan tanpa LCD≤85 ℃)
Pambuka
Aplikasi
Data Teknis
Instalasi
Pambuka
Flowmeter ratometer tabung logam minangka alat ukur kuantitas aliran area variabel. Nduwe fitur kayata volume cilik, sawetara deteksi gedhe lan operasi sing trep. Iku utamané cocok kanggo ngukur jumlahe aliran media karo kacepetan aliran cilik lan jumlah aliran cilik.Intelligentized tabung logam rotameters duwe jinis indikasi lapangan lan jinis transmisi remot intelligentized. Mangkono menehi pelanggan karo spasi pilihan banget sudhut. Kajaba iku, prosesor mikro 16 bit majeng lan komponen industri sing berkualitas tinggi diadopsi ing instrumen kasebut, sing njamin kinerja flowmeter sing apik ing macem-macem kahanan aplikasi.
Kaluwihan
Kauntungan Rotameter Tabung Logam Vertikal Male Thread:
Sistem indikasi ganda
Pemisahan kopling magnetik lan sinyal magnetik
Tampilan digital kristal cair garis ganda
Dhiameter bolongan saka tabung ukur saka flowmeter wis rampung
Resistance kanggo suhu dhuwur lan tekanan dhuwur
Perlindhungan apik lan kinerja bledosan bledosan
Seri lengkap pola instalasi
Macem-macem pola sumber daya
Sirkuit terpadu banget
Fungsi piranti lunak sistematis lan pola komunikasi Hart standar
Aplikasi
Male Thread Digital Tampilan Vertikal Metal Tube Rotameter Aplikasi
Rotameter tabung logam nganggo struktur baja tahan karat 304 /316, sing bisa digunakake kanggo ngukur aliran cairan, gas, lan uap. Iku utamané cocok kanggo pangukuran aliran tingkat aliran kurang, sawetara aliran mikro, suhu dhuwur, meksa dhuwur, corrosive, medium konduktif utawa non-konduktif. digunakake ing petroleum, kimia, panganan, perawatan banyu lan industri liyane.
Perawatan banyu
Perawatan banyu
Industri Pangan
Industri Pangan
Industri Farmasi
Industri Farmasi
Petrokimia
Petrokimia
Industri Kertas
Industri Kertas
Pengawasan kimia
Pengawasan kimia
Industri Metalurgi
Industri Metalurgi
Drainase Umum
Drainase Umum
Industri Batubara
Industri Batubara
Data Teknis

Tabel 1: Lembar Data Flowmeter Area Variabel Tampilan Vertikal

Rentang pangukuran

Banyu (20 ℃)                  16~150000 l/h.

Udhara (0,1013MPa 20 ℃)       0,5 ~ 4000 m3/h.

Rasio kisaran 10:1 (Tipe Khusus 20:1).
Kelas akurasi 2.5 (Tipe khusus 1.5% utawa 1.0%).
Tekanan kerja

DN15~DN50 PN16 (jinis khusus 2.5MPa).

DN80~DN150 PN10 (Tipe khusus 1.6MPa).

Rating tekanan jaket 1.6MPa.

Suhu sedheng

Tipe normal -80 ℃ ~ + 220 ℃.

Tipe suhu dhuwur 300 ℃. Diantrekake karo jinis FEP ≤85 ℃.

Suhu sekitar

-40 ℃ ~ + 120 ℃ (Remote tampilan tanpa LCD≤85 ℃).

(Remote tampilan karo LCD≤70 ℃).

Viskositas dielektrik

1/4” NPT, 3/8” NPT 1/2” NPT≤5mPa.s

3/4" NPT, 1" NPT ≤250mPa.s

Output

Sinyal standar: sistem rong kabel 4 ~ 20mA (karo komunikasi HART).

Sinyal standar: sistem telung kabel 0 ~ 10mA.

Sinyal weker: 1. Output relay rong arah.

2.Saklar siji-cara utawa loro-pendekatan.

Output sinyal pulsa: 0-1KHz output terisolasi.

Proses sambungan

Tipe standar: 24VDC±20%.

Tipe AC: 220VAC(85~265VAC) (opsional).

Mode sambungan

Flange

Utas

Tri-jepit

Tingkat pangayoman

IP65/IP67.

Ex-mark

Intrinsik aman: ExiaIICT3~6. Jinis Exd: ExdIICT4~6.

Tabel 2: Tampilan Vertikal Variabel Area Flowmeter Rentang Aliran

Kaliber

(mm)

Nomer kerja Range aliran Penurunan tekanan kpa

Banyu L/h

Udhara m3/h Banyu Kpa hawa
Tipe normal Tipe anti karat Tipe normal
Tipe anti karat

Tipe normal

Tipe anti karat
15 1A 2.5~25 -- 0.07~0.7 6.5 - 7.1
1B 4.0~40 2.5~25 0.11~1.1 6.5 5.5 7.2
1C 6.3~63 4.0~40 0.18~1.8 6.6 5.5 7.3
1D 10~100 6.3~63 0.28~2.8 6.6 5.6 7.5
1E 16~160 10~100 0.48~4.8 6.8 5.6 8.0
1F 25~250 16~160 0.7~7.0 7.0 5.8 10.8
1G 40~400 25~250 1.0~10 8.6 6.1 10.0
1H 63~630 40~400 1.6~16 11.1 7.3 14.0
25 2A 100~1000 63~630 3~30 7.0 5.9 7.7
2B 160~1600 100~1000 4.5~45 8.0 6.0 8.8
2C 250~2500 160~1600 7~70 10.8 6.8 12.0
2D 400~4000 250~2500 11~110 15.8 9.2 19.0
40 4A 500~5000 300~3000 12~120 10.8 8.6 9.8
4B 600~6000 350~3500 16~160 12.6 10.4 16.5
50 5A 630~6300 400~4000 18~180 8.1 6.8 8.6
5B 1000~10000 630~6300 25~250 11.0 9.4 10.4
5C 1600~16000 1000~10000 40~400 17.0 14.5 15.5
80 8A 2500~25000 1600~16000 60~600 8.1 6.9 12.9
8B 4000~40000 2500~25000 80~800 9.5 8.0 18.5
100 10A 6300~63000 4000~40000 100~1000 15.0 8.5 19.2
150 15A 20000~100000 -- 600~3000 19.2 -- 20.3

Tabel 3: Pamilihan Model Flowmeter Area Variabel Tampilan Vertikal

QTLZ X X X X X X X X X
Indikator Kode
Indikator lokal Z
Indikator LCD karo ouput D
diameteripun normal Kode
DN15 -15
DN20 -20
DN25 -25
DN40 -40
DN50 -50
DN80 -80
DN100 -100
DN150 -150
Struktur Kode
Ngisor-ndhuwur /
Kiri-tengen (horizontal) H1
Kanan-kiwa (horizontal) H2
Sisih-sisih AA
Sisih ngisor LA
Sambungan benang S
Tri-jepit M
Bahan awak Kode
304SS R4
316LSS R6L
Hastelloy C Hc4
titanium Ti
Liner F46(PTFE) F
Monel M
Jinis indikator Kode
Iinear indicator (indikator pointer) M7
Indikator nonlinier (LCD Display) M9
Fungsi kombinasi (mung kanggo tampilan LCD) Kode
24VDC karo output 4 ~ 20mA S
24VDC karo komunikasi HART Z
daya baterei D
Fungsi tambahan Kode
Tabung ukur kanthi pengawetan termal / jaket insulasi panas T
Ukur suhu medium sing luwih dhuwur tinimbang 120.C HT
Ex-bukti: Kode
karo W
tanpa N
weker Kode
Weker siji K1
Weker loro K2
ora ana N
Instalasi
Pemasangan rotameter tabung logam
Flowmeter sing dipasang kudu njamin entri ≥5DN bagean pipa lurus, ngekspor bagean pipa lurus ora kurang saka 250mm; yen medium ngemot bahan ferromagnetic, Filter Magnetik kudu diinstal ing ngarepe flowmeter. (deleng  filter magnetik lan diagram diameter bagean pipa lurus )



1.Kanggo meter aliran dipasang,messthekake perpendicularity pipa ukuran luwih apik tinimbang 5 lan kudu dilengkapi bypass, gampang kanggo njaga lan resik lan ora mengaruhi produksi.
2.Monitoring lan sistem kontrol ing katup kontrol,kudu dipasang hilir saka flowmeter.Kanggo pangukuran gas,Kudu mesthekake meksa apa ora kurang saka 5 kaping mundhut meksa saka flowmeter, kanggo nggawe karya stabil flowmeter ing.
3. Sadurunge nginstal flowmeter, Pipa kudu welding slag purging resik; Nalika instalasi kanggo mbusak komponen ngunci ing meter aliran; nalika digunakake sawise instalasi, Alon-alon mbukak tutup kontrol, Aja karusakan kejut  flow meter
Kirim Pitakonan Panjenengan
Diekspor menyang luwih saka 150 negara ing ndonya, 10000 set / kapasitas produksi sasi!
Hak cipta © Q&T Instrument Co., Ltd. Kabeh hak dilindhungi undhang-undhang.
Nyokong: Coverweb