Nā huahana
Meter Kahe Kanikani Nui
Meter Kahe Kanikani Nui
Meter Kahe Kanikani Nui
Meter Kahe Kanikani Nui

Meter Kahe Kanikani Nui

pololei: ±0.5 %
Hiki hou: ±0.2%
viscosity: 0.1 ~ ±7 m/s
Ana pōʻaiapuni: 50mS. (20 manawa/s, e ohi i 64 mau ikepili hui)
Hōʻike: Hōʻike LCD kukui hope
Hoʻolauna
Palapala noi
ʻIkepili ʻenehana
Hoʻokomo
Hoʻolauna
He kūpono no ke ana mau ʻana i ke kahe a me ka wela o nā wai maʻemaʻe a ʻaʻahu ʻole me ka ʻole o ka nui o nā mea i hoʻokuʻu ʻia a i ʻole ke kinoea.
Kākoʻo i ke kahawai hoʻokahi a me nā kaila he nui i ka manawa like, inā ʻano ʻole a pili ʻole paha kekahi o ke kahawai, hiki iā ia ke hoʻololi maʻalahi i ke kahawai hoʻokahi e hana.
Pono
Nā Pōmaikaʻi a me nā pōʻino ʻole o ka Multi-Channel Ultrsonic Flow Meter
ʻO ka ʻāpana ʻāpana paipu kahi ʻano ana e hoʻohana ai i kahi flange e hoʻopili pololei i ka ʻāpana ʻāpana paipu me ka pipeline e ana ʻia. Hoʻoponopono kēia sensor i ka pilikia o nā mea ʻike waho a me nā plug-in i hana ʻia e ke kanaka a i ʻole ka pololei ʻole o ka pipeline parameter i ka wā o ke kaʻina hana. ʻO nā hewa ke kumu i ka pilikia o ka emi ʻana o ke ana pololei, nona nā ʻano o ke ana kiʻekiʻe, kūpaʻa maikaʻi, a me ka mālama maʻalahi.
Palapala noi
Hiki ke hoʻopili i ka mīkini kani kani ultrasonic multi-channel e lilo i hoʻokahi calorimeter a hoʻohana nui ʻia i ke kaʻina hana, ke ana ʻana, ka hoʻoponopono kalepa.
Hoʻoponopono wai
Hoʻoponopono wai
ʻoihana lāʻau lapaʻau
ʻoihana lāʻau lapaʻau
Petrokimika
Petrokimika
Nānā Kemika
Nānā Kemika
ʻOihana Metallurgical
ʻOihana Metallurgical
Auwai Aupuni
Auwai Aupuni
ʻIkepili ʻenehana

Papa 1: Mul-Channel Ultrasonic Flowmeter Specification

Ka pololei ±0.5 %
Hiki hou ±0.2%
Viscosity 0.1 ~ ±7 m/s
Ana pōʻaiapuni 50mS. (20 manawa/s, hōʻiliʻili i nā ʻikepili hui 64)
Hōʻike Hōʻike LCD kukui hope
Hookomo 2-ala ʻelua-uea PT1000
Hoʻopuka 4~20mA, Pulse, OCT, RS485
Hana ʻē aʻe Hoʻomanaʻo helu kahe lā, mahina, makahiki
Hana hewa ʻike ponoʻī
Ka lōʻihi o ke kaula Max.100m
Pipe inner dia. 50mm ~1200mm
Paipu ʻO ke kila, ke kila ʻole, ka hao, PVC, ka paipu sima a ʻae i ka paipu me ke kapa
Paipu pololei Upstream≥10D, Downstream≥5D, Pump outlet≥30D
Media Wai, Wai kai, ʻAkika solution, ʻaila ʻaila, Gasoline, Aila lanahu, Diesel, Alcohol,
Hiki i ka pia a me nā wai like ʻole ke hoʻoili i nā nalu kani ultrasonic
ʻAhuehue ≤10000 ppm, haʻahaʻa haʻahaʻa haʻahaʻa
Mahana -10~150℃
kuhikuhi kahe Hiki ke ana ʻokoʻa i mua a me ka hoʻohuli ʻana i ke kahe, a hiki ke ana i ke kahe ʻupena
Mahana Mea hoʻokipa: -10-70 ℃; Nani:-30 ℃ ~ +150 ℃
Haʻahaʻa Mea hoʻokipa: 85%RH
Lako ikehu DC24V, AC220V
Mea kino kino Ke kila kalapona, SUS304, SUS316

Pākuʻi 2: Mili-Kānana Ultrasonic Flowmeter kikoʻī

QTDS-30 XXX X X X X X
Kaliber 50~2000 mm
Mea Kino Ke kila kalapona C
SS304 S0
SS316 S1
Pumi inoa 0.6 Mpa P1
1.0 MPa P2
1.6 MPa P3
2.5 MPa P4
Nā mea kūikawā ʻē aʻe P5
Hoʻopuka 4-20mA, Pulse, OCT, RS485 O
Kapili huikau I
mamao R
Hoʻohui Flange 1
Hoʻokomo
Nui-kanal ultrasonic kahe ana mika pono hoʻokomo
ʻO ka ʻāpana paipu kahi i loaʻa ai ka mea ʻike o ka pipe-segment ultrasonic flowmeter pono e hoʻopiha mau ʻia me kahi kahe mau o ka wai (wai) ʻaʻole e lūlū. Pono kēia i kahi o ka mea ʻike ma ka haʻahaʻa o ka paipu. Pono ka mea hana a me ka wahi i hoʻokomo ʻia i ka sensor mai kahi kumu hoʻopilikia.
He ʻelua ʻāpana ke kumu hoʻopilikia:
1. ʻO nā kumu hoʻopilikia e hiki ke hoʻoulu i ka haʻalulu mechanical o ka wai i ana ʻia (wai), e like me nā paila wai, nā mīkini hoʻolako wai, etc.
2. Nā kumu hoʻopilikia electromagnetic e hiki ai ke hōʻeha i ka hōʻailona mea kani, e like me nā mea hoʻololi, nā kaʻa mana kiʻekiʻe, nā keʻena hoʻololi pinepine, nā lako uila uila kiʻekiʻe, a me nā kumu hoʻopilikia electromagnetic ʻē aʻe.
E hoʻouna i kāu nīnau
Hoʻokuʻu ʻia i nā ʻāina ʻoi aku ma mua o 150 a puni ka honua, 10000 sets/month production capacity!
Kuleana kope © Q&T Instrument Co., Ltd. Mālama ʻia nā kuleana a pau.